Quick Link
Quick Contact
Address
6 building,No 98, Fulian 1 road,Baoshan district, Shanghai, China.
Tel
86-021-80392549
Our Newsletter
Subscribe to our newsletter for discounts and more.
The ATV610D75N4 is a 75 kW (100 hp) Altivar 610 variable frequency drive for 380 to 460 V three-phase supplies, built for the fan, pump, compressor and conveyor duty that sits behind most industrial production lines. It is a standard-load 75 kW drive that also runs 55 kW heavy-duty motor loads, so one variable frequency drive can cover a conveyor motor and the pump that feeds the process without buying two models.
An integrated C3 EMC filter is built into this ATV610 variable frequency drive, rated for up to 50 m of motor cable. On a production line where the drive sits in a cabinet next to robot controllers and sensors, that filter is the difference between a clean installation and an EMC problem that only appears when the conveyor starts.
The ATV610 variable frequency drive accepts both asynchronous and synchronous motors, and the 75 kW rating delivers 0.1 to 500 Hz output with a 2.5 kHz rated switching frequency adjustable from 1 to 8 kHz, and stores 16 preset speeds. The enclosure is IP20 with forced ventilation, 290 mm wide and 323 mm deep, with a net weight of 53 kg.
Commissioning of the variable frequency drive follows the ATV610 logic: three analog inputs that can be configured for 0 to 10 V, 0 to 20 mA or a temperature probe, six digital inputs, relay outputs and a Modbus RTU serial port on two-wire RS485. Slot A accepts a Profibus DP V1 card, a logic and analog I/O expansion card or a relay output card, so the drive can join the control architecture the line already uses instead of the other way around.
| Reference | ATV610D75N4 | Product Range | Altivar ATV610 |
| Motor Power (Standard Load) | 75 kW / 100 hp | Motor Power (Heavy Duty) | 55 kW / 75 hp |
| Supply | 380...460 V, 3 phase, 50/60 Hz +/-5% | Output Frequency | 0.1...500 Hz |
| Continuous Output Current | 145 A at 2.5 kHz (standard load) | Transient Current | 160 A for 60 s (standard load) |
| Integrated EMC Filter | C3, 50 m maximum motor cable | Protection Index | IP20, forced ventilation |
| Communication | Modbus RTU, 2-wire RS485 | Option Slot | Slot A: Profibus DP V1, I/O or relay card |
| Width x Depth | 290 mm x 323 mm | Net Weight | 53 kg |
| Ambient Temperature | -15...45 C without derating | Relative Humidity | 5...95%, non-condensing |
| Parameter | Standard Load | Heavy Duty |
| Motor power | 75 kW / 100 hp | 55 kW / 75 hp |
| Line current at 380 V | 147.9 A | 115.8 A |
| Line current at 460 V | 130.2 A | 101.7 A |
| Continuous output current | 145 A | 106 A |
| Transient current, 60 s | 160 A | 159 A |
| Apparent power at 460 V | 103.7 kVA | 81.0 kVA |
Q1. What does ATV610D75N4 mean in the part number?
ATV610 is the Altivar 610 range of variable frequency drive, D75 is a 75 kW standard-load rating and N4 indicates the 380 to 460 V three-phase version with an integrated C3 EMC filter.
Q2. Can this variable frequency drive run a 55 kW heavy duty motor?
Yes. The same variable frequency drive is rated 55 kW / 75 hp for heavy duty, with 106 A continuous output and 159 A transient for 60 s, so the variable frequency drive covers both duty classes.
Q3. How long can the motor cable be with the built-in filter?
The integrated C3 EMC filter on this ATV610 supports up to 50 m of motor cable, which is why the variable frequency drive usually needs no external EMC filter in the cabinet.
Q4. Which networks does it support?
Modbus RTU on two-wire RS485 is standard, with 4.8 to 38.4 kbit/s and up to 247 addresses. Slot A accepts a Profibus DP V1 communication card when the line uses Profibus.
Q5. What is the switching frequency range?
2.5 kHz rated on this variable frequency drive, adjustable from 1 to 8 kHz. Raising it reduces audible motor noise on a conveyor line, at the cost of slightly higher drive losses inside the ATV610.
Q6. What ambient temperature is allowed?
-15 to 45 C without derating, and 45 to 60 C with derating. Storage range is -40 to 70 C, and humidity up to 95% non-condensing is acceptable.
Q7. How much space does it need?
290 mm wide and 323 mm deep at 53 kg. Because the 75 kW variable frequency drive is force ventilated, the cabinet needs filtered air and clearance above and below the unit.
Q8. Does it control synchronous motors?
Yes. The ATV610 variable frequency drive supports asynchronous and synchronous motors and the unit can be configured for standard constant torque, optimized torque or variable torque control.